Nuclear power
Emergency drain cooler
Product Name: Emergency drain cooler
Project Name: Tianwan nuclear power
Security Level: nuclear grade 3
Warranty rating: QSA2
Working medium: reactor coolant / equipment cooling water
Maximum pressure / temperature: 17.6 MPa / 350 ℃
Heat transfer area: 20 square meters
Device Diameter: DN340
Detailed
The project is Tianwan nuclear power plant control system volume and boron emergency drain cooler of the project, the original equipment for the Russian imports, snake tube type heat transfer tubes, a leak has occurred in the course. My company and the Shanghai Nuclear Engineering Research and Design Institute, analyzed by use of a heat exchanger conditions, to the heat exchanger structure has been transformed, the heat exchanger type to U-tube type.